Axes
Radonix control board axes are labeled as Axis[n], where n represents the axis number. A passive axis cannot be placed between active ones, and a gantry axis must always be the last axis in the sequence.
The axes on the control board connect to servo and stepper motors via a DB15 connector according to Table 2 and Figure 19.
Table 2 – Axis Pin Assignments
| Pin | Function |
|---|---|
| 1 | VCC |
| 2 | Direction - |
| 3 | Direction + |
| 4 | Pulse - |
| 5 | Pulse + |
| 6 | Servo On |
| 7 | Servo Ready |
| 8 | Encoder Zero |
| 9 | Alarm Reset |
| 10 | GND |
| 11 | GND |
| 12 | GND |
| 13 | GND |
| 14 | GND |
| 15 | GND |
| GND |
Updated 8 months ago