Axes
Radonix control board axes are labeled as Axis[n], where n represents the axis number. A passive axis cannot be placed between active ones, and a gantry axis must always be the last axis in the sequence.
The axes on the control board connect to servo and stepper motors via a DB15 connector according to Table 2 and Figure 19.

Table 2 – Axis Pin Assignments
Pin | Function |
---|---|
1 | VCC |
2 | Direction - |
3 | Direction + |
4 | Pulse - |
5 | Pulse + |
6 | Servo On |
7 | Servo Ready |
8 | Encoder Zero |
9 | Alarm Reset |
10 | GND |
11 | GND |
12 | GND |
13 | GND |
14 | GND |
15 | GND |
GND |